You've fitted a fast NVMe SSD, but copies crawl, games load no quicker than before or a benchmark comes in well below the speed on the box. Before you assume the drive is faulty, it's worth knowing that most slow NVMe drives are healthy and simply running in the wrong slot, getting too hot, filling up or missing a firmware update. This guide uses Microsoft's Windows command documentation, the CrystalDiskInfo documentation and Samsung's Magician software page.
Step 1: Measure it fairly
The speeds printed on the box are maximum sequential read and write figures, measured in ideal conditions. Everyday tasks such as booting Windows or loading a game read lots of small files, which is much slower on every SSD. So a drive that "only" hits a fraction of its rated speed while copying a folder of small files may be working normally.
To get a fair comparison, run one benchmark with the same settings each time, on a drive that isn't busy. Your SSD maker's own tool often includes one: Samsung Magician has a Performance Benchmark test with adjustable test size and chunk size, for example. Note the result so you can tell whether a fix helps.
Step 2: Check the PCIe link it's running at
This is the most common cause. An NVMe drive connects through PCIe lanes, and the generation (PCIe 3.0, 4.0 or 5.0) and lane count (usually x4) it negotiates set its top speed.
The free tool CrystalDiskInfo shows this in its Transfer Mode field, in the format "current transfer mode | supported transfer mode". If you see something like PCIe 4.0 x4 on both sides, the link is fine. If the first value is lower than the second, for example PCIe 3.0 x4 or PCIe 4.0 x2, the drive is being held back by the slot or a setting.
Common reasons:
The slot is a lower generation. Many motherboards have one M.2 slot wired to the CPU and others to the chipset, often at different PCIe generations. A PCIe 5.0 drive in a PCIe 4.0 slot runs at PCIe 4.0 speeds. Our PCIe 4.0 vs PCIe 5.0 SSD comparison explains what each generation delivers.
The slot has fewer lanes. Some M.2 slots run at x2, or drop to x2 when another slot or SATA port is in use.
Lane sharing. On many boards, fitting a drive in a particular M.2 slot disables SATA ports or reduces the lanes to a PCIe slot, or the other way round.
A BIOS setting. Some boards let you set the PCIe generation for each M.2 slot. If it's been set to a lower generation, put it back to Auto.
Your motherboard manual has a table showing what each M.2 slot supports and what it shares. Move the drive to the fastest slot that's suitable, usually the top one nearest the CPU, then check CrystalDiskInfo again.
Step 3: Check for heat
NVMe SSDs slow themselves down (throttle) when they get too hot, which mostly shows up during long copies or installs. CrystalDiskInfo and maker tools such as Samsung Magician show the drive's temperature, so watch it during a large transfer. If speeds start high and then fall away as the temperature climbs, heat is the likely cause.
Fixes include fitting the motherboard's M.2 heatsink (remember to remove the plastic film from the thermal pad), adding a heatsink if the drive doesn't have one, and improving case airflow over the slot. A drive squeezed under a hot graphics card can suffer most. Our SSD heatsink vs no heatsink guide explains when one matters.
Step 4: Free up space and understand the cache
Most consumer SSDs use part of their flash as a fast write cache (often called an SLC cache). Large writes run quickly until that cache fills, then drop to the slower speed of the underlying flash. On many drives the cache shrinks as the drive fills up, so a nearly full SSD can feel much slower for big copies.
If your drive is close to full, clear space and leave some free. Drives that use QLC flash or have no DRAM cache tend to slow down more once their cache is exhausted. Our TLC vs QLC SSD and DRAM vs DRAM-less SSD comparisons explain why.
Step 5: Make sure TRIM is on
TRIM lets Windows tell the SSD which blocks are no longer in use, which helps it keep write speeds up. It's on by default, but it's worth checking, especially after cloning a drive or changing settings.
Search for Command Prompt, right-click it and choose Run as administrator.
Type fsutil behavior query DisableDeleteNotify and press Enter.
Microsoft's documentation describes this as the command to check whether TRIM is enabled; the setting disables (1) or enables (0) delete notifications, which Microsoft says are also known as trim. So NTFS DisableDeleteNotify = 0 means TRIM is on for NTFS drives, and 1 means it's off.
To turn it back on, type fsutil behavior set DisableDeleteNotify 0 and press Enter.
You can also run a manual retrim. In the same administrator window, type defrag C: /L, which Microsoft's documentation describes as performing a retrim on the volume (swap C: for the right drive letter). Windows' Optimise Drives tool can run this kind of optimisation on a schedule, so leave it switched on.
Step 6: Update firmware and drivers
SSD makers fix bugs, including performance problems, through firmware updates. Use your drive maker's tool to check: Samsung Magician offers firmware updates for Samsung drives, for example, though Samsung notes that features such as Firmware Update don't support non-Samsung SSDs. Back up important files before updating firmware.
Also update your motherboard BIOS and chipset drivers from the board maker's or AMD's or Intel's site, as these affect how the M.2 slots and chipset behave.
Step 7: Check the drive's health
If the link is right, temperatures are fine, there's free space, TRIM is on and firmware is current, but the drive is still slow, check its health. CrystalDiskInfo reports a health status from the drive's own SMART data, and our guide on how to check SSD health explains what the readings mean. If the drive shows warnings or errors, back up your data straight away and contact the maker about a warranty claim. If the drive is disappearing from Windows rather than just running slowly, see our guide to an SSD not showing up.
Our verdict
A slow NVMe SSD is usually a healthy drive held back by its setup. Check the PCIe link in CrystalDiskInfo first and move the drive to a full-speed slot if it isn't running at its supported generation and lane count. Then rule out heat, a nearly full drive, TRIM being off and old firmware, in that order. Only treat the drive as faulty once those checks are done and its health readings show problems.